Maintenance

Specifications

Specifications

Standard Tightening Torques Bolted Joints

All bolted joints are tightened to the torque required by Epiroc Standard K 4369:01 K (metric) and 4368K/-01K (imperial) unless otherwise stated. In such cases, this torque is specified in the maintenance instructions of the module in question.

Epiroc Standard Torques

Size

Strength Class

Torque

Tolerance ±

Nm

lbf.ft

Nm

lbf.ft

M6

8.8

8

6

2

1.5

M8

8.8

20

15

5

3.6

M10

8.8

41

30

10

7.3

M12

8.8

73

54

18

13.2

M14

8.8

115

85

25

18.4

M16

8.8

185

136

45

33

M20

8.8

355

262

85

62

M24

8.8

600

443

150

110

M12 x 1.25

10.9

135

100

6

4.4

M16 x 1.25

10.9

315

232

15

11

M18 x 1.25

10.9

460

340

20

15

M6

12.9

14

10

3

2.2

M8

12.9

34

25

8

5.9

M10

12.9

70

52

17

12.5

M12

12.9

120

89

30

22

M14

12.9

195

144

45

33

M16

12.9

315

232

75

55.3

M20

12.9

600

443

150

110.6

M24

12.9

1020

752

250

184.3

Type Designation Signs for Ordering Spare Parts

Type designation signs are posted on the larger components. Always quote the type designation and serial number when ordering spare parts or making inquiries regarding the products. Type designations and serial numbers are also specified in Machines Online (MOL). Spare parts can be ordered from Epiroc.